Control # |
Air Terminal Type |
Control Sys. |
Control Supplier |
Controller Model |
Sequence |
Heating Coils |
Fan Controller |
Fan Start / Stop |
Fan Adjust |
|
|
|
|
|
|
|
|
|
|
SD-D-8000A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
|
|
|
|
SD-D-8000D |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
|
|
|
|
SD-D-8000M |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
|
|
|
|
SD-D-8001A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
H.W. (Proportional) |
|
|
|
SD-D-8001D |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
H.W. (Proportional) |
|
|
|
SD-D-8002A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
H.W. (2-Position) |
|
|
|
SD-D-8002D |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
H.W. (2-Position) |
|
|
|
SD-D-8004A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Step) |
|
|
|
SD-D-8004D |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Step) |
|
|
|
SD-D-8005A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-8005D |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-8006A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Discharge Temp Limiting) |
|
|
|
SD-D-8006D |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Discharge Temp Limiting) |
|
|
|
SD-D-8007A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Htg & Clg (Auto Changeover) |
|
|
|
|
SD-D-8007D |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Htg & Clg (Auto Changeover) |
|
|
|
|
SD-D-8007M |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Htg & Clg (Auto Changeover) |
|
|
|
|
SD-D-8007R |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Htg & Clg (Auto Changeover) |
|
|
|
|
SD-D-8027A |
Single Duct |
DDC |
Anemostat |
Simply VAV |
VAV Htg & Clg (Auto Changeover) |
H.W. (Proportional) |
|
|
|
SD-D-AA01 |
Single Duct |
DDC |
American Automatrix |
|
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-AA02 |
Single Duct |
DDC |
American Automatrix |
|
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-AD02 |
Single Duct |
DDC |
Andover |
I2866-V |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-AD08 |
Single Duct |
DDC |
Andover |
b3866-V |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-AD10 |
Single Duct |
DDC |
Andover |
I2866-V |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-D006 |
Single Duct |
DDC |
Delta Controls |
DVC-4322A |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-D007 |
Single Duct |
DDC |
Delta Controls |
DVC-4322A |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-AL07 |
Single Duct |
DDC |
Automated Logic |
ZN141v+ / ZN341v+ |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-AL03 |
Single Duct |
DDC |
Automated Logic |
ZN141v+ / ZN341v+ |
VAV Cooling |
ERC (Step) |
|
|
|
SD-D-AL06 |
Single Duct |
DDC |
Automated Logic |
ZN141v+ / ZN341v+ |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-AT01 |
Single Duct |
DDC |
Alerton |
VAViH-SD |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-AT02 |
Single Duct |
DDC |
Alerton |
VAV-SD |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-AT14 |
Single Duct |
DDC |
Alerton |
VLC-853 |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-DC06 |
Single Duct |
DDC |
Distech Controls |
ECC-VAV |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-H014 |
Single Duct |
DDC |
Honeywell |
CVL4022AS-VAV1 |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-J025 |
Single Duct |
DDC |
Johnson Controls |
MS-VMA-16xx |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-J026 |
Single Duct |
DDC |
Johnson Controls |
MS-VMA-16xx |
VAV Cooling |
ERC (Step) |
|
|
|
SD-D-J027 |
Single Duct |
DDC |
Johnson Controls |
MS-VMA-16xx |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-J028 |
Single Duct |
DDC |
Johnson Controls |
FX-PCV-16xx |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-J029 |
Single Duct |
DDC |
Johnson Controls |
FX-PCV-16xx |
VAV Cooling |
ERC (Step) |
|
|
|
SD-D-J030 |
Single Duct |
DDC |
Johnson Controls |
FX-PCV-16xx |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-J031 |
Single Duct |
DDC |
Johnson Controls |
LX-VAVLF-1 |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-J034 |
Single Duct |
DDC |
Johnson Controls |
AP-VMA-14xx |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-J035 |
Single Duct |
DDC |
Johnson Controls |
AP-VMA-14xx |
VAV Cooling |
ERC (Step) |
|
|
|
SD-D-J036 |
Single Duct |
DDC |
Johnson Controls |
AP-VMA-14xx |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-D-J045 |
Single Duct |
DDC |
Johnson Controls |
|
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-SN23 |
Single Duct |
DDC |
Schneider Electric |
TAC Xenta 281 |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-SN24 |
Single Duct |
DDC |
Schneider Electric |
TAC Xenta 102-AX |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S188 |
Single Duct |
DDC |
Siemens |
550-767FN |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S189 |
Single Duct |
DDC |
Siemens |
|
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S190 |
Single Duct |
DDC |
Siemens |
550-767FN |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S191 |
Single Duct |
DDC |
Siemens |
550-767EN |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S192 |
Single Duct |
DDC |
Siemens |
|
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S193 |
Single Duct |
DDC |
Siemens |
DXR2.M12PX-102B |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S194 |
Single Duct |
DDC |
Siemens |
DXR2.M12PX-102K |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-D-S195 |
Single Duct |
DDC |
Siemens |
540-100N |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-A-5200 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling |
H.W. (Optional) |
|
|
|
SD-A-5201 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling |
ERC (Step) |
|
|
|
SD-A-5202 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling |
H.W. (2-Position) |
|
|
|
SD-A-5203 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling |
H.W. (Proportional) |
|
|
|
SD-A-5204 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling |
ERC (Proportional) |
|
|
|
SD-A-5220 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Morning Warm-Up |
|
|
|
|
SD-A-5221 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Morning Warm-Up |
ERC (Step) |
|
|
|
SD-A-5222 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Morning Warm-Up |
H.W. (2-Position) |
|
|
|
SD-A-5223 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Morning Warm-Up |
H.W. (Proportional) |
|
|
|
SD-A-5224 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Morning Warm-Up |
ERC (Proportional) |
|
|
|
SD-A-5240 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover) |
|
|
|
|
SD-A-5241 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover) |
ERC (Step) |
|
|
|
SD-A-5242 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover) |
H.W. (2-Position) |
|
|
|
SD-A-5243 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover) |
H.W. (Proportional) |
|
|
|
SD-A-5244 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover) |
ERC (Proportional) |
|
|
|
SD-A-5080 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Constant Volume |
|
|
|
|
SD-A-5281 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Constant Volume |
ERC (Step) |
|
|
|
SD-A-5282 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Constant Volume |
H.W. (2-Position) |
|
|
|
SD-A-5283 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Constant Volume |
H.W. (Proportional) |
|
|
|
SD-A-5284 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Constant Volume |
ERC (Proportional) |
|
|
|
SD-A-5085 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-5001 |
Constant Volume |
|
|
|
|
SD-A-5290 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-4702 |
Duct Static Pressure Control - Bypass/Relief |
|
|
|
|
SD-A-5291 |
Single Duct |
Analog Elect. |
Anemostat |
CSP-4702 |
Duct Static Pressure Control - Bypass/Relief |
|
|
|
|
SD-A-5046 |
Static Pressure Control |
Analog Elect. |
Anemostat |
CSP-4702 |
Duct Static Pressure Control - Bypass/Relief |
|
|
|
|
SD-A-5047 |
Static Pressure Control |
Analog Elect. |
Anemostat |
CSP-4702 |
Duct Static Pressure Control - Bypass/Relief |
|
|
|
|
FS-D-8000A |
Fan Pwr-Series |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
|
|
24VAC |
Manual (at box) |
FS-D-8001A |
Fan Pwr-Series |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
H.W. (Proportional) |
|
24VAC |
Manual (at box) |
FS-D-8002A |
Fan Pwr-Series |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
H.W. (2-Position) |
|
24VAC |
Manual (at box) |
FS-D-DC01 |
Fan Pwr-Series |
DDC |
Distech Controls |
ECC-VAV |
VAV Cooling |
ERC (Step) |
|
24VAC |
Manual (at box) |
FS-A-5200 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling |
|
|
24VAC |
Manual (at box) |
FS-A-5201 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling |
ERC (Step) |
|
24VAC |
Manual (at box) |
FS-A-5220 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling (Night Cycling) |
|
|
24VAC |
Manual (at box) |
FS-A-5221 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling (Night Cycling) |
ERC (Step) |
|
24VAC |
Manual (at box) |
FS-A-5224 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling (Night Cycling) |
ERC (Proportional) |
|
24VAC |
Manual (at box) |
FS-A-5225 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling (Night Cycling, Damper Closes) |
ERC (Step) |
|
24VAC |
Manual (at box) |
FS-A-5227 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling (Night Cycling) |
ERC (Step) |
|
24VAC |
Manual (at box) |
FS-A-5240 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling (Night Shut Down) |
|
|
24VAC |
Manual (at box) |
FS-A-5243 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Cooling (Night Shut Down) |
H.W. (Proportional) |
|
24VAC |
Manual (at box) |
FS-A-5260 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover)(w/Night Shutdown) |
|
|
24VAC |
Manual (at box) |
FS-A-5264 |
Fan Pwr-Series |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover)(w/Night Cycling) |
ERC (Proportional) |
|
24VAC |
Manual (at box) |
ES-D-8000A |
Fan Pwr-Series ECM |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
|
ECM |
24VAC |
Automation |
ES-D-8000D |
Fan Pwr-Series ECM |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
|
ECM |
24VAC |
Automation |
ES-D-8001A |
Fan Pwr-Series ECM |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
H.W. (Proportional) |
ECM |
24VAC |
Automation |
ES-D-8004A |
Fan Pwr-Series ECM |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Step) |
ECM |
24VAC |
Automation |
ES-D-8004D |
Fan Pwr-Series ECM |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Step) |
ECM |
24VAC |
Automation |
ES-D-8006A |
Fan Pwr-Series ECM |
DDC |
Anemostat |
Simply VAV |
VAV Htg & Clg (Auto Changeover) |
H.W. (Proportional) |
ECM |
24VAC |
Automation |
ES-D-J002 |
Fan Pwr-Series ECM |
DDC |
Johnson Controls |
FEC26XX |
VAV Cooling |
H.W. (Optional) |
ECM |
24VAC |
Automation |
ES-D-J003 |
Fan Pwr-Series ECM |
DDC |
Johnson Controls |
FEC26XX |
VAV Cooling |
H.W. (Optional) |
ECM |
24VAC |
Automation |
FP-D-8005A |
Fan Pwr-Parallel |
DDC |
Anemostat |
Simply VAV |
VAV Cooling |
ERC (Proportional) |
ECM |
24VAC |
Automation |
EP-D-0006 |
Fan Pwr-Parallel ECM |
DDC |
Field Installed |
|
VAV Cooling |
ERC (Step) |
ECM |
24VAC |
Manual (at box) |
EP-D-9005A |
Fan Pwr-Parallel ECM |
DDC |
Anemostat |
Conquest |
VAV Cooling |
ERC (Proportional) |
ECM |
24VAC |
Automation |
EP-D-9005C |
Fan Pwr-Parallel ECM |
DDC |
Anemostat |
Conquest |
VAV Cooling w/ CO2 Sensing Thermostat |
ERC (Proportional) |
ECM |
24VAC |
Automation |
ES-A-5263 |
Fan Pwr-Series ECM |
Analog Elect. |
Anemostat |
CSP-5001 |
VAV Htg & Clg (Auto Changeover) |
H.W. (Proportional) |
ECM |
24VAC |
Automation |
DD-D-8000A |
Dual Duct |
DDC |
Anemostat |
Simply VAV |
CAV Max Cooling and Heating - Minimum Mixing |
|
|
|
|
DD-D-9000A |
Dual Duct |
DDC |
Anemostat |
Conquest |
CAV Max Cooling and Heating - Minimum Mixing |
|
|
|
|
DD-D-TR01 |
Dual Duct |
DDC |
Trane |
UC-4001 |
VAV Cooling |
|
|
|
|
BR-A-5201 |
Bypass / Relief |
Analog Elect. |
Anemostat |
MEP-4802 |
VAV Cooling |
|
|
|
|
BR-A-5202 |
Bypass / Relief |
Analog Elect. |
Anemostat |
MEP-4802 |
VAV Htg & Clg (Auto Changeover) |
|
|
|
|
BR-A-5203 |
Bypass / Relief |
Analog Elect. |
Anemostat |
MEP-4802 |
VAV Cooling |
H.W. (2-Position) |
|
|
|
BR-A-5204 |
Bypass / Relief |
Analog Elect. |
Anemostat |
MEP-4802 |
VAV Cooling |
H.W. (Proportional) |
|
|
|
|
|
|
|
|
|
|
|
|
|